Free cookie consent management tool by TermsFeed Policy Generator

Opened 16 years ago

Closed 14 years ago

Last modified 14 years ago

#208 closed defect (done)

Closing the view of the sequential engine doesn't stop the engine

Reported by: gkronber Owned by: swagner
Priority: medium Milestone: HeuristicLab 3.3.0
Component: Optimization.Views Version: 3.3
Keywords: Cc:

Description


Change History (10)

comment:1 Changed 16 years ago by swagner

  • Milestone changed from 3.0 to 3.2
  • Version changed from 3.0 to 3.2

comment:2 Changed 16 years ago by gkronber

A good solution is probably to check if the engine is still running and show a warning dialog before closing the view.

comment:3 Changed 16 years ago by swagner

  • Milestone changed from 3.2 to Iteration 0

Milestone 3.2 deleted

comment:4 Changed 15 years ago by swagner

  • Component changed from SequentialEngine to Optimization.Views
  • Status changed from new to assigned
  • Version changed from 3.2 to 3.3

comment:5 Changed 15 years ago by swagner

Fixed for HL 3.3.0 in r2955.

comment:6 Changed 15 years ago by swagner

  • Status changed from assigned to new

comment:7 Changed 15 years ago by swagner

Added missing null check in r2956.

comment:8 Changed 14 years ago by swagner

  • Resolution set to fixed
  • Status changed from new to closed

comment:9 Changed 14 years ago by swagner

  • Milestone changed from Iteration 4 to Current

Milestone Iteration 4 deleted

comment:11 Changed 14 years ago by swagner

  • Milestone changed from Current to HeuristicLab 3.3.0

Milestone Current deleted

Note: See TracTickets for help on using tickets.