Free cookie consent management tool by TermsFeed Policy Generator

Opened 13 years ago

Closed 13 years ago

#1404 closed defect (done)

ProgrammableOperator "forgets" assemblies when they are recompiled

Reported by: epitzer Owned by: epitzer
Priority: medium Milestone: HeuristicLab 3.3.4
Component: Operators.Programmable Version: 3.3.4
Keywords: Cc:

Description (last modified by epitzer)

When referencing non standard assemblies these are simply "forgot" when opening again and the assembly has been recompiled in the meantime.

Change History (7)

comment:1 Changed 13 years ago by epitzer

  • Description modified (diff)

comment:2 Changed 13 years ago by epitzer

  • Owner changed from swagner to epitzer
  • Status changed from new to assigned

comment:3 Changed 13 years ago by epitzer

Use only the assembly name without version information when activating assemblies in ProgrammableOperator (r5781)

comment:4 Changed 13 years ago by epitzer

  • Owner changed from epitzer to swagner
  • Status changed from assigned to reviewing

comment:5 Changed 13 years ago by swagner

  • Milestone changed from HeuristicLab Backlog to HeuristicLab 3.3.4

comment:6 Changed 13 years ago by swagner

  • Owner changed from swagner to epitzer
  • Status changed from reviewing to readytorelease

Thanks for implementing this.

comment:7 Changed 13 years ago by swagner

  • Resolution set to done
  • Status changed from readytorelease to closed
  • Version changed from 3.3.2 to 3.3.4
Note: See TracTickets for help on using tickets.